Introduction:


Equipped with large LCD displayer, DGA2010 is a micro-computer controlled GC with programmed 8-grade temperature rising function. Adopted with the advanced technology, DGA2010 has the function of power off protection, over-temperature protection, “0℃” protection, non-gas protection, auto ignition, and etc.


It has the characteristics of reliable performance, compact design, convenient operation, and good expandability. It has the special function of temperature tracking for column. Its standard configuration is FID & TCD while with the expanding detectors like ECD, FPD, and NPD as well as methane transforming furnace. It is also capable of configuring FID amplifier.


Now DGA2010 has been widely used in the industries like oil, chemistry, pesticides, wine, environment protection, epidemic prevention, universities, scientific research and etc.


1. Working Environment

Temperature: 0~30℃

Relative Humidity: <85%

No Strong Electromagnetic Field

No Corrosive Gas

Stable Working Table without Vibration

Power Supply: AC220V±10%,50Hz±0.5Hz

Power Consumption: 2KW


2. Technical Parameters


2.1 Temperature Controlling

2.1.1 Chamber Temperature of Chromatographic Column

Temperature Range: RT + 8℃~420℃

Temperature Increment: 1℃

Temperature Accuracy: ±0.1℃ when < 200℃; ±0.2℃ when > 200℃

Temperature Uniformity: <1%

Temperature Error between Displaying & Real Temperature: <2%

Temperature Ramp Grades: 8 Grades Linear

Temperature Ramp Rate: 1~30℃/min with increment of 1℃/min

Time Range: 0~255 min with increment of 1 minute

Temperature Repeatability: <2%

Max Heating Power: 1500W

Temperature Sensor: PT100


2.1.2 Temperature of Vaporizing Room

Temperature Controlling Precision: ±0.1℃ when <200℃; ±0.2℃ when >200℃

Temperature Range: <420℃

Heater: Standing Heating Facility with 100W Heater

Temperature Sensor: PT100


2.1.3 Chamber Temperature of FID

Temperature Controlling Precision: ±0.1℃ when <200℃; ±0.2℃ when >200℃

Temperature Range: <420℃

Heater: Horizontal Heating Facility with 2×90W Heaters

Temperature Sensor: PT100


2.1.4Chamber Temperature of TCD

Temperature Controlling Precision: ±0.1℃ when <200℃; ±0.2℃ when >200℃

Temperature Range: <420℃

Heater: Standing Heating Facility with 2×90W Heaters

Temperature Sensor: PT100


2.2 TCD

Sensitivity: S≥3000mv·ml/mg(Benzene, H2

Noise: ≤0.02mv

Drift: ≤0.1mv/h

Built-in Amplifier

Semi-pervasion 100Ω bridge tungsten-rhenium wire

Constant Current Source Supply


2.3 FID

Detection Limit: M≤2×10-11g/s (Benzene/SO2)

Noise: ≤5×10-13A

Drift: ≤5×10-12A/30min

Detection Limit on Programmed Temperature Control Mode: M≤1×10-9g/s

Drift on Programmed Temperature Control Mode: ≤5×10-12A

All-collecting Polar Corundum Nozzle

Platinum Ignition Wire


2.4 Weight & Dimension

Dimension: 660(Width)× 460(Height)× 430(Depth)

Weight: 60kg


3. Optional Facilities

3.1 Recorder

-- Bench-top two-way recorder (Min Measurement: 1mv; Stroke Time: 1s)

-- Chromatogram Data Processor

-- Chromatogram Data Working Station (need to work with PC)

3.2 Gas Source

-- Nitrogen, Hydrogen, and Air tanks with Decompression Valves

-- Nitrogen, Hydrogen, and Air Generators

3.3 6-ways Gas Injector

3.4 Methane Reforming Furnace


4. Homework before Installation

4.1 The testing room should have no explosive and combustible materials; no strong electromagnetism should exist in the testing room. The testing room should be kept dry & clean with good air circulation. Stable working table should be provided.

4.2 Stable power supply with AC220V/50HZ/2KW is required; otherwise 3KW power regulator should be provided. The instrument body should be connected with earth.

4.3 Gas requirements: Carrier Gas 0.4Mpa, Hydrogen 0.25Mpa, and Air 0.3Mpa. High inert gases and clean air are required. When using the high-pressure tank, please read the instruction manual for the tank and get familiar with the using of high-pressure tank.

4.4 Please check the facilities & accessories of the packing list before installing the machine.


Product Tags:

Gas Chromatography

      

oil Gas Chromatography

      

Gas Chromatography analyzer

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

TOP Model DGA2010 Gas Chromatography, Equipped with large LCD displayer,advanced technology,compact design Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Chongqing Top Oil Purifier Co.,ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0